Word Addr Bits R/W Register Name Description
0x042 [1:0]
W reset_control(write) Writing a 1 to bit 0 initiates a TX digital
reset using the reset controller module. The
reset affects channels enabled in the reset_
ch_bitmask. Writing a 1 to bit 1 initiates a
RX digital reset of channels enabled in the
reset_ch_bitmask. This bit self-clears.
R reset_status(read) Reading bit 0 returns the status of the reset
controller TX ready bit. Reading bit 1
returns the status of the reset controller RX
ready bit. This bit self-clears.
Reset Controls –Manual Mode
0x044
[31:4,0] RW Reserved It is safe to write 0s to reserved bits.
[1] RW reset_tx_digital Writing a 1 causes the internal TX digital
reset signal to be asserted, resetting all
channels enabled in reset_ch_bitmask.
You must write a 0 to clear the reset
condition.
[2] RW reset_rx_analog Writing a 1 causes the internal RX analog
reset signal to be asserted, resetting the RX
analog logic of all channels enabled in
reset_ch_bitmask. You must write a 0 to
clear the reset condition.
[3] RW reset_rx_digital Writing a 1 causes the RX digital reset signal
to be asserted, resetting the RX digital
channels enabled in reset_ch_bitmask.
You must write a 0 to clear the reset
condition.
PMA Control and Status Registers
0x061 [31:0] RW phy_serial_loopback Writing a 1 to channel <n> puts channel <n>
in serial loopback mode. For information
about pre- or post-CDR serial loopback
modes, refer to Loopback Modes.
0x064 [31:0] RW pma_rx_set_locktodata When set, programs the RX CDR PLL to
lock to the incoming data. Bit <n>
corresponds to channel <n>.
0x065 [31:0] RW pma_rx_set_locktoref When set, programs the RX CDR PLL to
lock to the reference clock. Bit <n>
corresponds to channel <n>.
UG-01143
2015.05.11
XAUI PHY Register Interface and Register Descriptions
2-225
Implementing Protocols in Arria 10 Transceivers
Altera Corporation
Send Feedback
Page view 255
1 2 ... 251 252 253 254 255 256 257 258 259 260 261 ... 625 626

Comments to this Manuals

No comments

Praktica 256834 Handbücher

Bedienungsanleitungen und Benutzerhandbücher für Brückenkameras Praktica 256834.
Wir stellen 1 PDF-Handbücher Praktica 256834 zum kostenlosen herunterladen nach Dokumenttypen zur Verfügung Datenblatt


Praktica 256834 Datenblatt (2 Seiten)


Marke: Praktica | Kategorie: Bridge cameras | Größe: 0.41 MB |

 

Inhaltsverzeichnis





Weitere Produkte und Handbücher für Brückenkameras Praktica

Modelle Dokumententyp
259 309 Datenblatt   Praktica luxmedia 12-XS, 2 Seiten