Altera ByteBlasterMV User Manual Page 24

  • Download
  • Add to my manuals
  • Print
  • Page
    / 26
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 23
2–6 Altera Corporation
Software Instructions
Software
Instructions
The Altera Quartus II design software package provides the programmer
function required to configure or program devices using the ByteBlasterMV
download cable.
To configure or program one or more devices with the ByteBlasterMV cable and
the Quartus II Programmer, perform the following steps.
f
For a detailed explanation of the programming process, see the Programming
module of the Quartus II tutorial. See also the “Overview: Working with Chain
Description Files” and “Overview: Converting Programming Files” topics in
Quartus II Help.
1. Compile a project. The Quartus II Compiler generates a programming file,
such as a SOF, a POF, a Jam File (.jam), or a Jam Byte Code File (.jbc),
depending on the target device.
Table 2–6. ByteBlasterMV Cable DC Operating Conditions
Symbol Parameter Conditions Min. Max. Unit
V
IH
High-level input voltage V
CC
= 5.5 V 2.32 V
V
CC
= 3.6 V 1.53 V
V
CC
= 2.625 V 1.11 V
V
CC
= 1.89 V 0.80 V
V
IL
Low-level input voltage V
CC
= 4.5 V 1.36 V
V
CC
= 3.0 V 0.89 V
V
CC
= 2.375 V 0.71 V
V
CC
= 1.71 V 0.51 V
V
OH
5.0-V high-level output voltage V
CC
= 4.5 V, I
OH
=8mA 4.4 V
3.3-V high-level output voltage V
CC
= 3.0 V, I
OH
=4mA 2.9 V
2.5-V high-level output voltage V
CC
= 2.375 V, I
OH
= 2 mA 2.275 V
1.8-V high-level output voltage V
CC
= 1.71 V, I
OH
= 2 mA 1.61 V
V
OL
5.0-V low-level output voltage V
CC
= 5.5 V, I
OL
= 8 mA 0.125 V
3.3-V low-level output voltage V
CC
= 3.6 V, I
OL
= 4 mA 0.125 V
2.5-V low-level output voltage TTL load. V
CC
= 2.625 V,
I
OL
=2mA
0.125
I
CC
Operating current (no load) 50 mA