5–2 Chapter 5: Power Measurement
Power Design Example
Stratix III Development Kit User Guide © August 2008 Altera Corporation
The LEDs in Table 5–2 indicate the power-state values of the design example as
User_PB1 advances frequency.
The LEDs in Table 5–3 indicate the power-state values of the design example (and
number of output pins, when enabled by User_PB3) as User_PB2 advances resource
utilization.
The resource state (Table 5–3) controls the number of I/O pins used. Each resource
increment adds eight additional I/O pins (Table 5–3). Similarly, the overall design
frequency (Table 5–2) sets the toggle frequency of these I/O pins.
Table 5–2. Power State Indicators for Frequency
LED1 (C23) LED0 (F21) Frequency (MHz)
000
0133
1067
1 1 100
Table 5–3. Power State Indicators for Resources
LED6
(F19)
LED5
(C19)
LED4
(D19)
LED3
(A23)
LED2
(B23)
Resources
(%)
Number of
Outputs
0000058
000011016
000101524
000112032
001002540
001013048
001103556
001114064
010004572
010015080
010105588
010116096
0110065104
0110170112
0111075120
0111180128
1000085136
1000190144
1001095152
10011100160