Mentor VIP AE AXI3/4 User Guide, V10.2b
430
VHDL AXI3 and AXI4 Slave BFMs
set_write_response_valid_delay()
September 2013
AXI3 Example
-- Create a slave transaction. Creation returns tr_id to identify
-- the transaction.
create_slave_transaction(tr_id, bfm_index, axi_tr_if_0(bfm_index));
-- Set the write response channel BVALID delay to 3 ACLK cycles for the
-- tr_id transaction.
set_write_response_valid_delay(3, tr_id, bfm_index,
axi_tr_if_0(bfm_index));
AXI4 Example
-- Create a slave transaction. Creation returns tr_id to identify
-- the transaction.
create_slave_transaction(tr_id, bfm_index, axi4_tr_if_0(bfm_index));
-- Set the write response channel BVALID delay to 3 ACLK cycles for the
-- tr_id transaction.
set_write_response_valid_delay(3, tr_id, bfm_index,
axi4_tr_if_0(bfm_index));